03/2003
6-48
8850/ 510DP
SPS 510dp Change Tag Information, SPS 510dp
General Procedures
TAG: 6
CLASS: R
USE: All
MFG SERIAL NUMBERS:
NAME: HVPS
PURPOSE: To resolve LL-24 problems.
KIT NUMBER: 604K12880
REFERENCE: N/A
TAG: 7
CLASS: R
USE: All
MFG SERIAL NUMBERS:
NAME: Fuser Control Gate
PURPOSE: To provide a new fuser lamp harness with better insulation properties to with
stand the fuser heat.
KIT NUMBER: 604K12880
REFERENCE: N/A
TAG: 8
CLASS: R
USE: All
MFG SERIAL NUMBERS:
NAME: Fuser Latch Switch Location
PURPOSE: To ensure a more positive actuation of the Latch Switch in order to avoid having
to repeatedly shut the Fuser Drawer to actuate the switch.
KIT NUMBER: 604K12880
REFERENCE: N/A
TAG: 10
CLASS: R
USE: All
MFG SERIAL NUMBERS:
NAME: Fuser Latch Switch
PURPOSE: To provide the necessary Latches and shims t for the Fuser Drive Motor to cor-
rect the Fuser Drive Gears engagement.
KIT NUMBER: 604K16910
REFERENCE: N/A
TAG: 11
CLASS: R
USE: All
MFG SERIAL NUMBERS:
NAME:
PURPOSE: To provide a new Media Rolls Drive Motor bracket that provides a better
adjustment of the Media Rolls Drive Chain.
KIT NUMBER: 604K16990
REFERENCE: N/A
TAG: 13
CLASS: R
USE: All
MFG SERIAL NUMBERS:
NAME:
PURPOSE: The purpose is to provide an oiler end cap made of different material and add a
hole in the Fuser frame to accommodate the lamp wiring
KIT NUMBER: N/A
REFERENCE: PL 10.5