8.3 Advanced Autotuning
8-25
8
Adjustments
Confirm
Click Confirm to view the driving pattern
Detailed Setting
Create the reference pattern for setting the moment of inertia (mass) by changing the values with the
slider or by directly entering the values.
Next
Click Next to view the Reference Transmission box.
Cancel
Click Cancel to return to the main window without changing the conditions.
<If the moment of inertia (mass) ratio cannot be measured accurately>
If the torque (force) is limited, the moment of inertia (mass) ratio identification cannot be made correctly.
Adjust the setting of the limit or decrease the acceleration in Reference Selection so that the torque (force) will
not be limited.
CAUTION
The amount of movement is the value for each operation (a forward run or a reverse run). After several opera-
tions, the operation starting position may have moved in either direction. Confirm the operable range before each
measurement and operation.
Certain settings for the parameters or inertia size of the mechanism may result in overshooting or undershooting,
and cause the speed to temporarily exceed the maximum speed. Allow a margin when making the settings.