6.3.3 Initializing the Communications Settings
6-4
6.3.3 Initializing the Communications Settings
You use the communications setting switch (S1) to restore the Ethernet and MECHATROLINK-III communi-
cations settings to their factory settings.
• Type A01 SERVOPACK
• Type A02 SERVOPACK
If you turn ON the communications initialization pin, the SERVOPACK will start with the following commu-
nications settings.
Note: Pn880, Pn881, and Pn030 are not initialized.
Communications setting switch (S1)
12
OFF
ON
Pin on S1 Function Setting
1
Initializing the commu-
nications settings
OFF Normal mode (factory setting)
ON Initializes the communications settings.
2
Reserved
(Do not use.)
OFF (Do not change.)
Parameter Factory setting
IP Address 192.168.1.1
Station Address 0003H
Number of Transmission Bytes 0048