EasyManua.ls Logo

YASKAWA E-V-MD Series - Page 167

YASKAWA E-V-MD Series
321 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Adjustments
8.3.2 Advanced Autotuning Procedure
8-34
(4) Related Functions on Advanced Autotuning
Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically during advanced autotuning and
the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing
advanced autotuning.
Anti-Resonance Control Adjustment
This function reduces low vibration frequency, which the notch filter does not detect.
Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When you set this function to Auto Setting, vibration will be automatically detected during execution of auto-
tuning without a host reference and anti-resonance control will be automatically adjusted and set.
Vibration Suppression
The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is
generated mainly when positioning if the machine stand vibrates.
Usually, set this function to Auto Setting. (The vibration suppression function is factory-set to Auto Setting.)
When you set this function to Auto Setting, vibration will be automatically detected during execution of auto-
tuning without a host reference and vibration suppression control will be automatically adjusted and set. Set
this function to Not Auto Setting if you do not change the setting for vibration suppression before executing
autotuning without a host reference.
Note: This function uses model following control. Therefore, the function can be executed only if the mode selection is set
to 2 or 3.
Parameter Function When Enabled Classification
Pn460
n.0
Does not set the 1st notch filter automatically with
the utility function.
Immediately Tuning
n.1
[Factory setting]
Sets the 1st notch filter automatically with the util-
ity function.
n.0
Does not set the 2nd notch filter automatically with
the utility function.
n.1
[Factory setting]
Sets the 2nd notch filter automatically with the util-
ity function.
Parameter Function When Enabled Classification
Pn160
n.0
Does not use the anti-resonance control automati-
cally with the utility function.
Immediately Tuning
n.1
[Factory setting]
Uses the anti-resonance control automatically with
the utility function.
Parameter Function When Enabled Classification
Pn140
n.0
Does not use the vibration suppression function
automatically with the utility function.
Immediately Tuning
n.1
[Factory setting]
Uses the vibration suppression function automati-
cally with the utility function.

Table of Contents