8.6 Anti-Resonance Control Adjustment Function
8-63
8
Adjustments
(1) With Undetermined Vibration Frequency
1.
In the SigmaWin+ main window, click Tuning - Tuning.
Supplemental Information
If you are using more than one axis, the Axis Selection Dialog Box is displayed. Follow the instructions
in the Axis Selection Dialog Box to select the axis to adjust before you continue.
The following window will appear.
In the SigmaWin+ main window, click Tuning - Tuning.
2.
Click Execute.
The following window will appear.