5.3 Monitoring Machine Operation
5.3.3 Realtime Tracing
5-49
5
Debugging Programs
Edge ON or Edge OFF
Use these options to sample the data before and after a specified bit changes from OFF to
ON or from ON to OFF.
Edge ON: Edge OFF:
No. Item Description
Edge ON
Use these options to sample the data before and after a specified bit
changes from OFF to ON or from ON to OFF.
Target register (Bit type) Use this box to enter the target register.
Drag this icon to set the trigger position.
% Select the numeric value to set for the trigger position.
ms The maximum measurement time after the trigger is displayed in this box.
Edge OFF
Use this method to sample the data before and after a specified bit
changed status from ON to OFF.