EasyManua.ls Logo

YASKAWA T1000V - Page 293

YASKAWA T1000V
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.5 Drive Replacement
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual 293
Periodic Inspection &
Maintenance
7
Figure 7.8
Figure 7.8 Removable Terminal Board disconnected from the drive
Terminal Board Replacement
1. Replace the removable terminal block on the drive according to Figure 7.9
Figure 7.9
Figure 7.9 Terminal Board Replacement
2. Ensure the terminal block is firmly fastened to the connector.
Figure 7.10
Figure 7.10 Terminal Board Installed
3. Put the lower cover and the terminal cover back in place.
4. Once the drive has been replaced, check the drive unit selection setting in o2-04. For more information, refer to
o2-04: Drive Model Selection on page 215.
5. An oPE04 error may occur when replacing the drive or the removable terminal block. If the data on saved to the
terminal block is compatible, then set A1-03 = 5550. This will write the parameter settings stored in the terminal
block to the new drive.
Reset the appropriate Maintenance Monitors using parameters o4-01 through o4-13.
Place the terminal board below the
guide tracks in the plastic case of the
drive. Then push it gently down and
slide it toward the keypad until the
locking pin clicks into place.
Connector