B.3 Parameter Table
360 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
U2-05
Output Current at Previous
Fault
Displays the output current at the previous fault.
No signal output
avail.
<42>
<44>
AAA 84
U2-06
Motor Speed at Previous
Fault
Displays the motor speed at the previous fault.
No signal output
avail.
0.01
Hz
Α A − 85
U2-07
Output Voltage at Previous
Fault
Displays the output voltage at the previous fault.
No signal output
avail.
0.1 V A A A 86
U2-08
DC Bus Voltage at Previous
Fault
Displays the DC bus voltage at the previous fault.
No signal output
avail.
1 V A A A 87
U2-09
Output Power at Previous
Fault
Displays the output power at the previous fault.
No signal output
avail.
0.1
kW
AAA 88
U2-10
Torque Reference at
Previous Fault
Displays the torque reference at the previous fault.
No signal output
avail.
0.1% −Α− 89
U2-11
Input Terminal Status at
Previous Fault
Displays the input terminal status at the previous fault.
Displayed as in U1-10.
No signal output
avail.
–AAA8A
U2-12
Output Terminal Status at
Previous Fault
Displays the output status at the previous fault. Displays
the same status displayed in U1-11.
No signal output
avail.
–AAA8B
U2-13
Drive Operation Status at
Previous Fault
Displays the operation status of the drive at the previous
fault. Displays the same status displayed in U1-12.
No signal output
avail.
–AAA8C
U2-14
Cumulative Operation Time
at Previous Fault
Displays the cumulative operation time at the previous
fault.
No signal output
avail.
1 H A A A 8D
U2-15
Soft Starter Speed
Reference at Previous Fault
Displays the speed reference for the soft starter at the
previous fault.
No signal output
avail.
0.01
Hz
AAA 7E0
U2-16
Motor q-Axis Current at
Previous Fault
Displays the q-axis current for the motor at the previous
fault.
No signal
output
avail.
0.10% − A A 7E1
U2-17
Motor d-Axis Current
at
Previous Fault
Displays the d-axis current for the motor at the previous
fault.
No signal output
avail.
0.10% − A A 7E2
U3: Fault History
After 10 faults have occurred, the oldest fault saved to the fault history (U3-10) is deleted, and the most recent fault is displayed in U3-01.
<18>
U3-01 Most Recent Fault Displays the most recent fault.
No signal output
avail.
–AAA
90
(800)
U3-02 2nd Most Recent Fault Displays the second most recent fault.
No signal output
avail.
–AAA
91
(801)
U3-03 3rd Most Recent Fault Displays the third most recent fault.
No signal output
avail.
–AAA
92
(802)
U3-04 4th Most Recent Fault Displays the fourth most recent fault.
No signal output
avail.
–AAA
93
(803)
U3-05 5th Most Recent Fault Displays the fifth most recent fault.
No signal output
avail.
– A A A 804
U3-06 6th Most Recent Fault Displays the sixth most recent fault.
No signal output
avail.
– A A A 805
U3-07 7th Most Recent Fault Displays the seventh most recent fault.
No signal output
avail.
– A A A 806
U3-08 8th Most Recent Fault Displays the eighth most recent fault.
No signal output
avail.
– A A A 807
U3-09 9th Most Recent Fault Displays the ninth most recent fault.
No signal output
avail.
– A A A 808
U3-10 10th Most Recent Fault Displays the tenth most recent fault.
No signal output
avail.
– A A A 809
U3-11
Cumulative Operation Time
at Most Recent Fault
Displays the cumulative operation time at the most recent
fault.
No signal output
avail.
1 h A A A
94
(80A)
U3-12
Cumulative Operation Time
at 2nd Most Recent Fault
Displays the cumulative operation time at the second
most recent fault.
No signal output
avail.
1 h A A A
95
(80B)
U3-13
Cumulative Operation Time
at 3rd Most Recent Fault
Displays the cumulative operation time at the third most
recent fault.
No signal output
avail.
1 h A A A
96
(80C)
U3-14
Cumulative Operation Time
at 4th Most Recent Fault
Displays the cumulative operation time at the fourth most
recent fault.
No signal output
avail.
1 h A A A
97
(80D)
No. Name Description
Analog Output
Level
Unit
Control
Mode
Addr.
Hex
V/f
OL
V
P
M