Motor Type Induction Motors Permanent Magnet Motors Comments
Control Mode V/f V/f w/PG OLV CLV OLV/PM AOLV/PM CLV/PM
Type of
Applications
Motor Type IM IM IM IM PM IPM PM
Multi Motor YES
Motor data
unknown
YES
High Speed
Accuracy
YES YES YES YES YES YES
High Speed
Response
YES YES YES YES
Zero Speed
Control
YES YES YES
Torque Control
Operation
YES YES
Torque Limit
Operation
YES YES YES
PG Option Card
PG-B3 or
PG-X3
PG-B3 or
PG-X3
PG-X3
Control
Characteristics
Speed Control
Range
1:40 1:40 1:200 1:1500 1:20
1:20
1:100
1:1500
May fluctuate with
characteristics and
motor temperature.
May fluctuate with
characteristics and
motor temperature.
Enabled for 1:100
when n8-57, High
Frequency Injection,
is set to 1 (Enabled).
Speed Accuracy ±2 to 3% ±0.03% ±0.2% ±0.02% ±0.2% ±0.2% ±0.02%
Speed deviation rate
between speed
reference value and
motor speed (100%
= rated speed, motor
temperature 25 °C
±10 °C) when
operating at normal
status and when load
is stable.
Speed Response 3 Hz (approx.) 3 Hz (approx.) 10 Hz 50 Hz 10 Hz 10 Hz 50 Hz
Max. frequency of a
speed reference
signal that the drive
can follow may
fluctuate with
characteristics and
motor temperature.
Starting Torque 150% at 3 Hz 150% at 3 Hz
200% at
0.3 Hz
200% at
0 r/min
100% at
5% speed
100% at 5%
speed
200% at 0 r/min
200% at
0 r/min
Starting torque may
fluctuate with
characteristics and
motor temperature.
Performance may
differ by capacity.
200% at 0 r/min
enabled when n8-57,
High Frequency
Injection, is set to 1
(Enabled).