Motor Type Induction Motors Permanent Magnet Motors Comments
Control Mode V/f V/f w/PG OLV CLV OLV/PM AOLV/PM CLV/PM –
Type of
Applications
Motor Type IM IM IM IM PM IPM PM –
Multi Motor YES – – – – – – –
Motor data
unknown
YES – – – – – – –
High Speed
Accuracy
– YES YES YES YES YES YES –
High Speed
Response
– – YES YES – YES YES –
Zero Speed
Control
– – – YES – YES YES –
Torque Control
Operation
– – – YES – – YES –
Torque Limit
Operation
– – YES YES – – YES –
PG Option Card –
PG-B3 or
PG-X3
–
PG-B3 or
PG-X3
– – PG-X3 –
Control
Characteristics
Speed Control
Range
1:40 1:40 1:200 1:1500 1:20
1:20
1:100
1:1500
May fluctuate with
characteristics and
motor temperature.
May fluctuate with
characteristics and
motor temperature.
Enabled for 1:100
when n8-57, High
Frequency Injection,
is set to 1 (Enabled).
Speed Accuracy ±2 to 3% ±0.03% ±0.2% ±0.02% ±0.2% ±0.2% ±0.02%
Speed deviation rate
between speed
reference value and
motor speed (100%
= rated speed, motor
temperature 25 °C
±10 °C) when
operating at normal
status and when load
is stable.
Speed Response 3 Hz (approx.) 3 Hz (approx.) 10 Hz 50 Hz 10 Hz 10 Hz 50 Hz
Max. frequency of a
speed reference
signal that the drive
can follow may
fluctuate with
characteristics and
motor temperature.
Starting Torque 150% at 3 Hz 150% at 3 Hz
200% at
0.3 Hz
200% at
0 r/min
100% at
5% speed
100% at 5%
speed
200% at 0 r/min
200% at
0 r/min
Starting torque may
fluctuate with
characteristics and
motor temperature.
Performance may
differ by capacity.
200% at 0 r/min
enabled when n8-57,
High Frequency
Injection, is set to 1
(Enabled).
1.2 General Description
32