b9-01
(01DA)
Zero Servo Gain Zero Servo Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
Sets the position loop gain for the Zero Servo function.
Default: 5
Min.: 0
Max.: 100
220
b9-02
(01DB)
Zero Servo Completion
Width
Zero Servo Count
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
Sets the range to trigger an output terminal set for “Zero Servo
Complete” during Zero Servo operation.
Default: 10
Min.: 0
Max.: 16383
221