EasyManua.ls Logo

YASKAWA U1000 - N3: Overexcitation Braking; N5: Feed Forward Control; N6: Online Tuning

YASKAWA U1000
706 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
u
n3: Overexcitation Braking
No.
(Addr.
Hex)
Name LCD Display Description Values Page
n3-13
(0531)
Overexcitation
Deceleration Gain
Hflux Brake Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLV
Sets the gain applied to the V/f pattern during Overexcitation
Deceleration (L3-04 = 4).
Default: 1.10
Min.: 1.00
Max.: 2.00
336
u
n5: Feed Forward Control
No.
(Addr.
Hex)
Name LCD Display Description Values Page
n5-01
(05B0)
Feed Forward Control
Selection
Feedfoward Sel
0: Disabled
1: Enabled
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM CLV/PM
CLV
0: Disabled
1: Enabled
Default: 0
Range: 0, 1
337
n5-02
(05B1)
Motor Acceleration
Time
Motor Accel Time
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM CLV/PM
CLV
Sets the time required to accelerate the motor at the rated torque
from stop to rated speed.
Default:
<1> <2>
Min.: 0.001 s
Max.: 10.000 s
337
n5-03
(05B2)
Feed Forward Control
Gain
Feedfoward Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM CLV/PM
CLV
Sets the ratio between motor and load inertia. Lower this setting
if overshoot occurs at the end of acceleration.
Default: 1.00
Min.: 0.00
Max.: 100.00
338
<1> Default setting is determined by parameter E5-01, Motor Code Selection.
<2> Default setting is determined by parameters C6-01, Drive Duty Selection, and o2-04, Drive Model Selection.
u
n6: Online Tuning
No.
(Addr.
Hex)
Name LCD Display Description Values Page
n6-01
(0570)
Online Tuning
Selection
Online Tune Sel
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVOLV
0: Disabled
1: Line-to-line resistance tuning
2: Voltage correction. Setting not possible when Energy Saving
is enabled (b8-01).
Default: 0
Range: 0 to 2
338
n6-05
(05C7)
Online Tuning Gain R1 Comp Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVOLV
Decrease this setting for motors with a relatively large rotor
time constant.
Default: 1.0
Min.: 0.1
Max.: 50.0
339
B.11 n: Special Adjustments
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
559
B
Parameter List

Table of Contents

Other manuals for YASKAWA U1000