Name LCD Display Description Values Page
E2-11
(0318)
Motor Rated Power Mtr Rated Power
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLV
Sets the motor rated power in kilowatts (1 HP = 0.746 kW).
Automatically set during Auto-Tuning.
Default:
<1>
Min.: 0.00 kW
Max.: 650.00 kW
257
<1> Default setting is dependent on parameters C6-01, Drive Duty Selection, and o2-04, Drive Model Selection.
<2> Display is in the following units:
2o0028, 2o0042, and 4o0011 to 4o0027: 0.01 A units
2o0054 to 2o0248 and 4o0034 to 4o0930: 0.1 A units
u
E3: V/f Pattern for Motor 2
These parameters are hidden when a PM motor control mode has been selected for motor 1 (A1-02 = 5, 6, 7).
No.
(Addr.
Hex)
Name LCD Display Description Values Page
E3-01
(0319)
Motor 2 Control Mode
Selection
Mot 1 Contr Meth
0: V/f Control
1: V/f with PG
2: Open Loop Vector
3: Closed Loop Vect
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLV
0: V/f Control
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
Default: 0
Range: 0 to 3
258
E3-04
(031A)
Motor 2 Maximum
Output Frequency
Max Frequency
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV CLV
To set linear V/f characteristics, set the same values for E3-07
and E3-09.
In this case, the setting for E3-08 will be disregarded. Ensure
that the five frequencies are set according to the following rules
to prevent triggering an oPE10 fault:
E3-09 ≤ E3-07 < E3-06 ≤ E3-11 ≤ E3-04
Setting E3-11 to 0 disables both E3-11 and E3-12 and the above
conditions do not apply.
Output Voltage (V)
Frequency (Hz)
E3-05
E3-12
E3-13
E3-08
E3-10
E3-09 E3-07 E3-06 E3-11 E3-04
Note: E3-07 and E3-08 are only available in the
following control modes: V/f, V/f w/PG and
OLV.
Default:
<1>
Min.: 40.0
Max.: 400.0
258
E3-05
(031B)
Motor 2 Maximum
Voltage
Max Voltage
Default:
<1> <4>
Min.: 0.0 V
Max.: 255.0 V
<2>
258
E3-06
(031C)
Motor 2 Base Frequency Base Frequency
Default:
<1>
Min.: 0.0
Max.: E3-04
258
E3-07
(031D)
Motor 2 Mid Output
Frequency
Mid Frequency A
Default:
<1>
Min: 0.0
Max: E3-04
258
E3-08
(031E)
Motor 2 Mid Output
Frequency Voltage
Mid Voltage B
Default:
<1>
Min: 0.0 V
Max: 255.0 V
<2>
258
E3-09
(031F)
Motor 2 Minimum
Output Frequency
Min Frequency
Default:
<1>
Min.: 0.0
Max.: E3-04
258
E3-10
(0320)
Motor 2 Minimum
Output Frequency
Voltage
Min Voltage
Default:
<1>
Min: 0.0 V
Max: 255.0 V
<2>
258
E3-11
(0345)
<3>
Motor 2 Mid Output
Frequency 2
Mid Frequency B
Default: 0.0 Hz
Min.: 0.0
Max.: E3-04
258
E3-12
(0346)
<3>
Motor 2 Mid Output
Frequency Voltage 2
Mid Voltage B
Default: 0.0 V
Min.: 0.0
Max.: 255.0
<2>
258
E3-13
(0347)
<4>
Motor 2 Base Voltage Base Voltage
Default: 0.0 V
<4>
Min.: 0.0
Max.: 255.0
<2>
258
<1> Default setting is determined by parameter E3-01, Motor 2 Control Mode Selection. The value shown here is for V/f Control (0).
<2> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.
<3> Ignored when E3-11, Motor 2 Mid Output Frequency 2, and E3-12, Motor 2 Mid Output Frequency Voltage 2, are set to 0.
B.7 E: Motor Parameters
518
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual