B.19 Parameters Changed by Motor Code Selection (for PM Motors)
The following tables show parameters and default settings that change with the motor code selection E5-01 when Open Loop
Vector for PM motors is used.
u
Yaskawa SMRA Series SPM Motor
Table B.18 200 V, 1800 r/min Type Yaskawa SMRA Series SPM Motor Settings
No. Name Unit Default Settings
E5-01
Motor Code Selection (for PM Motors) 0002 0003 0005 0006 0008
Voltage Class V 200 200 200 200 200
Rated Power kW 0.4 0.75 1.5 2.2 3.7
Rated Speed r/min 1800 1800 1800 1800 1800
E5-02 Motor Rated Power (for PM Motors) kW 0.4 0.75 1.5 2.2 3.7
E5-03 Motor Rated Current (for PM Motors) A 2.1 4.0 6.9 10.8 17.4
E5-04 Number of Motor Poles (for PM Motors) 8 8 8 8 8
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω 2.47 1.02 0.679 0.291 0.169
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH 12.7 4.8 3.9 3.6 2.5
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH 12.7 4.8 3.9 3.6 2.5
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs
/rad
0 0 0 0 0
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/
(r/min)
62.0 64.1 73.4 69.6 72.2
E1-04 Maximum Output Frequency Hz 120 120 120 120 120
E1-05 Maximum Voltage V 200.0 200.0 200.0 200.0 200.0
E1-06 Base Frequency Hz 120 120 120 120 120
E1-09 Minimum Output Frequency Hz 6 6 6 6 6
C5-17 Motor Inertia
kgm
2
0.0007 0.0014 0.0021 0.0032 0.0046
n5-02 Motor Acceleration Time s 0.064 0.066 0.049 0.051 0.044
Table B.19 200 V, 3600 r/min Type Yaskawa SMRA Series SPM Motor Settings
No. Name Unit Default Settings
E5-01
Motor Code Selection (for PM Motors) 0103 0105 0106 0108
Voltage Class V 200 200 200 200
Rated Power kW 0.75 1.5 2.2 3.7
Rated Speed r/min 3600 3600 3600 3600
E5-02 Motor Rated Power (for PM Motors) kW 0.75 1.5 2.2 3.7
E5-03 Motor Rated Current (for PM Motors) A 4.1 8.0 10.5 16.5
E5-04 Number of Motor Poles (for PM Motors) 8 8 8 8
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω 0.538 0.20 0.15 0.097
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH 3.2 1.3 1.1 1.1
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH 3.2 1.3 1.1 1.1
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs
/rad
0 0 0 0
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/
(r/min)
32.4 32.7 36.7 39.7
E1-04 Maximum Output Frequency Hz 240 240 240 240
E1-05 Maximum Voltage V 200.0 200.0 200.0 200.0
E1-06 Base Frequency Hz 240 240 240 240
E1-09 Minimum Output Frequency Hz 12 12 12 12
C5-17 Motor Inertia
kgm
2
0.0007 0.0014 0.0021 0.0032