No.
(Addr.
Hex)
Name LCD Display Description Values Page
H5-11
(043C)
Communications
ENTER Function
Selection
Enter CommandSel
0: Enter Required
1: No EnterRequired
All Modes
0: Drive requires an Enter command before accepting any
changes to parameter settings.
1: Parameter changes are activated immediately without the
Enter command (same as V7).
Default: 0
Range: 0, 1
620
H5-12
(043D)
Run Command Method
Selection
Run CommandSel
0: FWD Run &REV
Run
1: Run & FWD/REV
All Modes
0: FWD/Stop, REV/Stop
1: Run/Stop, FWD/REV
Default: 0
Range: 0, 1
620
H5-17
(11A1)
Operation Selection
when Unable to Write
into EEPROM
Busy Enter Sel
0: No ROM Enter
1: RAM Enter
All Modes
Selects operation when an attempt is made to write data into
EEPROM via MEMOBUS/Modbus communications and
writing into EEPROM is not possible.
There is normally no need to change this parameter from the
default value
0: Cannot write into EEPROM
1: Write in RAM only
Default: 0
Range: 0, 1
620
H5-18
(11A2)
Filter Time Constant for
Motor Speed Monitoring
MtrSpd Monitor T
All Modes
Sets the filter time constant for monitoring the motor speed
from MEMOBUS/Modbus communications and
communication options.
Applicable MEMOBUS/Modbus registers are: 3EH, 3FH,
44H, ACH, and ADH
Default: 0 ms
Min.: 0
Max.: 100
620
<1> If this parameter is set to 0, the drive will be unable to respond to MEMOBUS/Modbus commands.
u
H6: Pulse Train Input/Output
No.
(Addr.
Hex)
Name LCD Display Description Values Page
H6-01
(042C)
Pulse Train Input
Terminal RP Function
Selection
Term RP Func Sel
0: Frequency Ref
1: PID Feedback
2: PID Set Point
3: PG Feedback
All Modes
0: Frequency reference
1: PID feedback value
2: PID setpoint value
3: V/f Control with Simple PG feedback (possible only when
using motor 1 in V/f Control)
Default: 0
Range: 0 to 3
306
H6-02
(042D)
Pulse Train Input
Scaling
Term RP Scaling
All Modes
Sets the terminal RP input signal frequency that is equal to
100% of the value selected in H6-01.
Default: 1440 Hz
Min.: 100
Max.: 32000
307
H6-03
(042E)
Pulse Train Input Gain Terminal RP Gain
All Modes
Sets the level of the value selected in H6-01 when a frequency
with the value set in H6-02 is input.
Default: 100.0%
Min.: 0.0
Max.: 1000.0
307
H6-04
(042F)
Pulse Train Input Bias Terminal RP Bias
All Modes
Sets the level of the value selected in H6-01 when 0 Hz is input.
Default: 0.0%
Min.: -100.0
Max.: 100.0
307
H6-05
(0430)
Pulse Train Input Filter
Time
Term RP Flt Time
All Modes
Sets the pulse train input filter time constant.
Default: 0.10 s
Min.: 0.00
Max.: 2.00
307
H6-06
(0431)
Pulse Train Monitor
Selection
Term MP Func Sel
All Modes
Select the pulse train monitor output function (value of the
o-oo part of Uo-oo).
For example, enter “501” for U5-01.
Default: 102
Range: 000 to 809
307
H6-07
(0432)
Pulse Train Monitor
Scaling
Term RP Scaling
All Modes
Sets the terminal MP output signal frequency when the monitor
value is 100%.
For example, to have the pulse train monitor output equal the
output frequency, set H6-06 to 102 and H6-07 to 0.
Default: 1440 Hz
Min.: 0
Max.: 32000
307