Push the connectors together so
no space remains between them.
A –Opening
Figure 7.27 Attach the Relay Connector
2□0248, 4□0216, 4□0240 4□0302 to 4□0414
Figure 7.28 Cooling Fan Unit
2.
Install the cooling fan unit and place the cable back into position.
Note: 1. Replace the whole unit when performing maintenance on the cooling fans.
2. Install the cooling fan unit while pulling the cable upward so that the cable does not get pinched between parts.
A – Pull the cable upwards
B – Bend 3 times
C – Hook
Figure 7.29 Install the Cooling Fan
3.
Thread the 4 fan unit screws into the proper holes approximately 2/3 of the way. Leave enough space to reinsert the
fan guard.
A –Screw locations
Figure 7.30 Attach the Cooling Fan Unit
7.4 Drive Cooling Fans
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
435