Register No. Contents
00CDH
Alarm Contents 7
bit 0 Power Supply Frequency Fault Detection (Fdv)
bit 1 Phase Order Detection Fault (SrC)
bit 2 Reserved
bit 3 Power Supply Undervoltage (AUv)
bit 4 to F Reserved
00CEH
Alarm Contents 8
bit 0 to D Reserved
bit E Snubber Discharge Resistor Overheat (SoH)
bit F Reserved
00CFH Reserved
00D0H
CPF Contents 1
bit 0, 1 Reserved
bit 2 Control Circuit Error (CPF02)
bit 3 Control Circuit Error (CPF03)
bit 4, 5 Reserved
bit 6 Control Circuit Error (CPF06)
bit 7 Control Circuit Error (CPF07)
bit 8 Control Circuit Error (CPF08)
bit 9, A Reserved
bit B Control Circuit Error (CPF11)
bit C Control Circuit Error (CPF12)
bit D Control Circuit Error (CPF13)
bit E Control Circuit Error (CPF14)
bit F Reserved
00D1H
CPF Contents 2
bit 0 Control Circuit Error (CPF16)
bit 1 Control Circuit Error (CPF17)
bit 2 Control Circuit Error (CPF18)
bit 3 Control Circuit Error (CPF19)
bit 4 Control Circuit Error (CPF20)
bit 5 Control Circuit Error (CPF21)
bit 6 Control Circuit Error (CPF22)
bit 7 Control Circuit Error (CPF23)
bit 8 Control Circuit Error (CPF24)
bit 9 Terminal Board not Connected (CPF25)
bit A Control Circuit Error (CPF26)
bit B Control Circuit Error (CPF27)
bit C Control Circuit Error (CPF28)
bit D Control Circuit Error (CPF29)
bit E Control Circuit Error (CPF30)
bit F Control Circuit Error (CPF31)
C.9 MEMOBUS/Modbus Data Table
636
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual