12-15
IM 01E30D01-01EN
<12. OUTLINE>
Item Specications
Applicable
Model
Code
General
Explosion
proof
AXR***G
AXR***C
Five-point
Calibration in
User-specied
Span (*8)
Aowtestnear0,25,50,75,and100%oftheuser-speciedspanisperformed
insteadofthestandardowtestandatestcerticate(QIC)issubmitted.Specifythe
spanowrateandunitwhenplacinganorder.
Specifythespan(100%owspan)whosecorrespondingowvelocityliesbetween
1.0 to 10 m/s and that is less than the maximum line capacity. Selectable range of
owratespanisshowingbelow.
Size:mm(in.) Selectablerangeofowratespan:m
3
/h
(Flow rate span velocity: m/s)
25 (1) 1.77 (1.0) to 11 (6.22)
40 (1.5) 4.53 (1.0) to 28 (6.30)
50 (2) 7.07 (1.0) to 56 (7.92)
65 (2.5) 12.0 (1.0) to 80 (6.70)
80 (3) 18.1 (1.0) to 126 (6.96)
100 (4) 28.3 (1.0) to 190 (6.72)
150 (6) 63.6 (1.0) to 380 (5.97)
200 (8) 113 (1.0) to 670 (5.92)
○ ○
SC
Bar-magnet for
operation of
magnet switches
(*6)
Bar-magnet for operation of magnet switches, with a case.
○ ○
BM
ATEX
Certication
ATEXExplosionproof
Read “HAZARDOUS AREA CLASSIFICATION”
–
○
KF2
FM Approval
FM Explosion proof
Read “HAZARDOUS AREA CLASSIFICATION”
–
○
FF1
CSA
Certication
CSA Explosion proof
Read “HAZARDOUS AREA CLASSIFICATION”
–
○
CF1
IECEx
Certication
IECEx Explosion proof
Read “HAZARDOUS AREA CLASSIFICATION”
–
○
SF2
TIISCertication
TIISameproof
Read “HAZARDOUS AREA CLASSIFICATION”
(Need to select optional code G11.)
–
○
JF3
Flameproof
packing adapter
for TIIS Flame-
proof Type (*7)
Oneameproofpackingadapterandoneblindplug. –
○
G11
Oneameproofpackingadapteraddition –
○
G32
*1:
Standard
+90-degree
rotation
+180-degree
rotation
–90-degree
rotation
Optional Code
RA
Optional Code
RB
Optional Code
RC
Connection
Indicator
Electrical Connection
Indicator
*2: When specifying the optional code BSC, it is advisable to specify the optional code GA, GC, or GD at the same time to prevent poten-
tialleakagecausedbythedifferenceinelasticitybetweentheowtubeandchloroprenegaskets.
*3: Allowable temperature and pressure with the optional code BSC (only for Gaskets: Chloroprene rubber) are equivalent to Valqua
#2010.
*4: Allowable temperature and pressure with the optional code BSF (only for Gaskets: PTFE-sheathed non-asbestos) are equivalent to
Valqua #7030 (S).
*5: Read description of “Gasket” in the “Wetted Part Material”.
Specialgasketsareinsertedbetweentheowtubeandthegroundingringorgroundingelectrode.
*6: Keep the bar-magnet in the case because of the powerful magnetic force.
*7: FortheTIISameprooftype,selectoptionalcodeG11.Incaseoftwoameproofpackingadapters,selectoptionalcodeG32withG11.
Available only for JIS G1/2 female electric connection.
*8: Standardowtestconditionisfollows;
- General-purpose use (25 to 200 mm)/ Exprosion proof type (25 to 100 mm): span; 2 m/s, test point; 0, 30, 100%
- Exprosion proof type (150, 200 mm): span; 2 m/s, test point; 0, 35, 100%