9 - 18 DS457 Fixed Mount Imager Integration Guide
Nixdorf Beep/LED Options
Select Nixdorf Mode B to indicate when the imager beeps and turns on its LED after a decode.
Ignore Unknown Characters
Unknown characters are characters the host does not recognize. Select Send Bar Codes with Unknown
Characters to send all bar code data except for unknown characters. The imager issues no error beeps.
Select Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown
character. The imager issues an error beep.
*Normal Operation
(Beep/LED immediately after decode)
Beep/LED After Transmission
Beep/LED After CTS Pulse
*Send Bar Code
(with unknown characters)
Do Not Send Bar Codes
(with unknown characters)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 and is the answer not in the manual?

Zebra DS457 Specifications

General IconGeneral
TypeFixed bar code reader
Wavelength655 nm
Sensor type-
Scanner type1D/2D
Optical sensor resolution752 pixels
Standard interfacesUSB
Connectivity technologyWired
Input voltage5 V
Power consumption450 mA
SafetyETL, VDE, CETL, EN60950, Ctick, VCCI
CertificationFCC, RoHS
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Cables includedUSB, VGA
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth58.4 mm
Width62 mm
Height29.2 mm
Weight111 g