11 - 22 DS457 Fixed Mount Imager Integration Guide
Ignore to End of Field (D)
This operator causes all characters after a template to be ignored. Use this as the last character in a template
expression. Examples for the template 999D:
Template Incoming data Output
999D 123-PED 123
357298 357
193 193
Skip Until (P1)
This operator allows skipping over characters until a specific character type or a literal string is detected. It can
be used in two ways:
P1ct
Where:
P1 is the Skip Until operator
c is the type of character that triggers the start of output
t is one or more template characters
P1"s"t
Where:
P1 is the Skip Until operator
"s" is one or more literal string characters (see Literal String (" and +) on page 11-20) that trigger the
start of output
t is one or more template characters
D
P
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 and is the answer not in the manual?

Zebra DS457 Specifications

General IconGeneral
TypeFixed bar code reader
Wavelength655 nm
Sensor type-
Scanner type1D/2D
Optical sensor resolution752 pixels
Standard interfacesUSB
Connectivity technologyWired
Input voltage5 V
Power consumption450 mA
SafetyETL, VDE, CETL, EN60950, Ctick, VCCI
CertificationFCC, RoHS
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Cables includedUSB, VGA
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth58.4 mm
Width62 mm
Height29.2 mm
Weight111 g

Related product manuals