198
Specifications
Technical Specifications
For device technical specifications, go to www.zebra.com.
SE965 Decode Zone
The table below lists the typical distances for selected barcode densities. The minimum element width (or
“symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol.
Table 27 SE965 Decode Distances
Symbol Density/
Barcode Type
Barcode Content/ Contrast
Note 1
Typical Working Ranges
Near Far
5.0 mil
Code 128
1234
80% MRD
1.2 in
3.05 cm
7.7 in
19.56 cm
5.0 mil
Code 39
ABCDEFGH
80% MRD
1.2 in
3.05 cm
12.5 in
31.75 cm
7.5 mil
Code 39
ABCDEF
80% MRD
1.1 in
2.79 cm
18.5 in
46.99 cm
10 mil
Code 128
1234
80% MRD
1.2 in
3.05 cm
Note 3
19.0 in
48.26 cm
13 mil
100% UPC
012345678905
80% MRD
1.6 in
4.06 cm
27.0 in
68.58 cm
15 mil
Code 128
1234
80% MRD
1.0 in
2.54 cm
Note 3
29.5 in
74.93 cm
20 mil
Code 39
123
80% MRD
1.4 in
3.56 cm
Note 3
52.0 in
132.08 cm