12.19.7 Cable for the tilt sensor control
Note: The tilt sensor control cables must be suitable for a 600 V
environment.
Parameter Specification
Number of cores 2 x 2 twisted pair (4 core)
Diameter (inside) 0.75 to 2.5 mm² (1.5 to 4.9 kcmil)
Diameter (outside) 5 to 10 mm (0.20 to 0.39 in)
Conductor Fine strand copper wire
Insulation PVC or other material that is serviceable
for outdoor use and UV-protected
Minimum test 1.5 kV
Strip lenght 11 mm (0.43 in)
12.19.8 Ethernet cable
Parameter
Specification
Type Shielded (tinned copper braid)
Number of (twisted) pairs 4 x 2
Core identification Acc. to DIN 47100
Cross section 0.5 - 0.75 mm²
Diameter 5 - 10mm
Conductor Fine strand copper wire
Insulation PVC that is serviceable for outdoor use, UV-
protected, and oil resistant
Characteristic impedance 120 Ω ± 10%
Voltage rating 600 VAC
Test voltage 1.5 kV
Ambient temperature range -40ºC to 80ºC
Technical data
100 9AKK107992A6488-EN | 004