Procedure
1. Prepare ferrules for the wires that are mentioned below. Refer to section 11.2.
2. Connect the wires to the primary power cabinet:
a. Loosen the terminal screws on X8-1, X8-2, and X8-3 of the primary power
cabinet.
b. Connect the wires as mentioned in the below tabel.
• Use the illustration as a reference.
• For the connection procedure, refer to section 11.5.
Wire from wire from
secondary power cabi-
net
Connect to primary
power cabinet
Terminal name
(A) CAN H X8-1 CANH IN
(B) CAN L X8-2 CANL IN
(C) CAN shield X8-3 GND CAN IN
c. Tighten the terminal screws to the correct torque. For the specification,
refer to section 12.14.
18 17 16192122 2024 23 15 14 13 12
11
10
9 8 7 6 5 4
18 17 16192122 2024 23 15 14 13 12
11
10
9 8 7 6 5 4
PE
CanH_IN
GND_CAN_IN
CanL_IN
DC-Guard B
-X8
Power Cabinet Primary
DC-Guard B GND
IL_IN_3
IL_OUT_3
DC-Guard A 2
DC-Guard A 2 GND
IL_IN_2
IL_OUT_2
DC-Guard A 1
DC-Guard A 1 GND
IL_IN_1
IL_OUT_1
PE
PE
PE
CanH_OUT
CanL_OUT
GND_CAN_OUT
Internal USE
Internal USE
Internal USE
Internal USE
Internal USE
Internal USE
123
PE
CanH_IN
GND_CAN_IN
CanL_IN
DC-Guard B
-X8
Power Cabinet Secondary
DC-Guard B GND
IL_IN_3
IL_OUT_3
DC-Guard A 2
DC-Guard A 2 GND
IL_IN_2
IL_OUT_2
DC-Guard A 1
DC-Guard A 1 GND
IL_IN_1
IL_OUT_1
PE
PE
PE
CanH_OUT
CanL_OUT
GND_CAN_OUT
Internal USE
Internal USE
Internal USE
Internal USE
Internal USE
Internal USE
123
C
B
A
Electrical installation of the power cabinet
9AKK107992A6488-EN | 004 51