4. Connect these wires:
V+
wire (A) from the primary power cabinet, wire number 1, to the terminal
X2-1 (I)
V+
wire (B) from the charge post, wire number 1, to the terminal X2-2 (J)
V-
wire (C) from the primary power cabinet, wire number 2, to the terminal
X2-3 (K)
V-
wire (D) from the charge post, wire number 2, to the terminal X2-4 (L)
Rin
wire (E) from the primary power cabinet, wire number 3, to the terminal
X2-5 (M)
Rin
wire (F) from the charge post, wire number 3, to the terminal X2-6 (N)
Rout
wire (G) from the primary power cabinet, wire number 4, to the
terminal X2-7 (O)
Rout
wire (H) from the charge post, wire number 4, to the terminal X2-8 (P)
5. Tighten the screws to the correct torque. For the specification, refer to section
12.14.
Electrical installation of the power cabinet