iv
If the robot is working in cleaning cells that are not emptied when the robot is switched off, the oil
may be replaced more frequently.
See also Analyzing the water content in gearbox oil on page 193.
v
The battery low alert (38213 Battery charge low) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
vi
The battery low alert (38213 Battery charge low) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See Operating manual - IRC5 with
FlexPendant for instructions.
124 Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
3 Maintenance
3.2.2 Maintenance schedule
Continued