Loading...
Inspecting, mechanical stops
Use this procedure to inspect the additional mechanical stops.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
to the robot, before entering the robot working area.
1
Shown in figure Location of
mechanical stops on page 161.
Make sure no additional stops are damaged.2
Make sure the stops are properly attached.3
Correct tightening torque, additional mechanical
stops:
Axis 1 = 120 Nm.
Article number is specified in
Required equipment on page 162.
If any damage is detected, the mechanical stops must
be replaced.
Correct attachment screws:
Axis 1: M12 x 40, quality 12.9.
Axis 2: M16 x 50
Axis 3: M16 x 60
4
Product manual - IRB 6640 Foundry Prime 163
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
3 Maintenance
3.3.13 Inspecting the additional mechanical stops
Continued

Table of Contents