Function IEC 61850 IEC 60617 IEC-ANSI
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
low stage, instance 2
DPH3LPDOC2 3I> -> (2) 67-1 (2)
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
high stage, instance 1
DPH3HPDOC1 3I>> -> (1) 67-2 (1)
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
high stage, instance 2
DPH3HPDOC2 3I>> -> (2) 67-2 (2)
Non-directional earth-fault protection, low stage,
instance 1
EFLPTOC1 Io> (1) 51N-1 (1)
Non-directional earth-fault protection, low stage,
instance 2
EFLPTOC2 Io> (2) 51N-1 (2)
Non-directional earth-fault protection, high stage,
instance 1
EFHPTOC1 Io>> (1) 51N-2 (1)
Non-directional earth-fault protection, high stage,
instance 2
EFHPTOC2 Io>> (2) 51N-2 (2)
Non-directional earth-fault protection, instantaneous
stage
EFIPTOC1 Io>>> 50N/51N
Directional earth-fault protection, low stage, instance 1 DEFLPDEF1 Io> -> (1) 67N-1 (1)
Directional earth-fault protection, low stage, instance 2 DEFLPDEF2 Io> -> (2) 67N-1 (2)
Directional earth-fault protection, high stage DEFHPDEF1 Io>> -> 67N-2
Admittance based earth-fault protection, instance 1 EFPADM1 Yo> -> (1) 21YN (1)
Admittance based earth-fault protection, instance 2 EFPADM2 Yo> -> (2) 21YN (2)
Admittance based earth-fault protection, instance 3 EFPADM3 Yo> -> (3) 21YN (3)
Transient/intermittent earth-fault protection INTRPTEF1 Io> -> IEF 67NIEF
Harmonics based earth-fault protection
1)
HAEFPTOC1 Io>HA 51NHA
Non-directional (cross-country) earth fault protection,
using calculated Io
EFHPTOC1 Io>> (1) 51N-2 (1)
Negative-sequence overcurrent protection, instance 1 NSPTOC1 I2> (1) 46 (1)
Negative-sequence overcurrent protection, instance 2 NSPTOC2 I2> (2) 46 (2)
Negative-sequence overcurrent protection, instance 3 NSPTOC3 I2> (3) 46 (3)
Negative-sequence overcurrent protection, instance 4 NSPTOC4 I2> (4) 46 (4)
Phase discontinuity protection PDNSPTOC1 I2/I1> 46PD
Residual overvoltage protection, instance 1 ROVPTOV1 Uo> (1) 59G (1)
Residual overvoltage protection, instance 2 ROVPTOV2 Uo> (2) 59G (2)
Residual overvoltage protection, instance 3 ROVPTOV3 Uo> (3) 59G (3)
Three-phase undervoltage protection, instance 1 PHPTUV1 3U< (1) 27 (1)
Three-phase undervoltage protection, instance 2 PHPTUV2 3U< (2) 27 (2)
Three-phase undervoltage protection, instance 3 PHPTUV3 3U< (3) 27 (3)
Three-phase overvoltage protection, instance 1 PHPTOV1 3U> (1) 59 (1)
Three-phase overvoltage protection, instance 2 PHPTOV2 3U> (2) 59 (2)
Three-phase overvoltage protection, instance 3 PHPTOV3 3U> (3) 59 (3)
Positive-sequence undervoltage protection, instance 1 PSPTUV1 U1< (1) 47U+ (1)
Positive-sequence undervoltage protection, instance 2 PSPTUV2 U1< (2) 47U+ (2)
Negative-sequence overvoltage protection, instance 1 NSPTOV1 U2> (1) 47O- (1)
Negative-sequence overvoltage protection, instance 2 NSPTOV2 U2> (2) 47O- (2)
Frequency protection, instance 1 FRPFRQ1 f>/f<,df/dt (1) 81 (1)
Frequency protection, instance 2 FRPFRQ2 f>/f<,df/dt (2) 81 (2)
Frequency protection, instance 3 FRPFRQ3 f>/f<,df/dt (3) 81 (3)
Frequency protection, instance 4 FRPFRQ4 f>/f<,df/dt (4) 81 (4)
Frequency protection, instance 5 FRPFRQ5 f>/f<,df/dt (5) 81 (5)
Frequency protection, instance 6 FRPFRQ6 f>/f<,df/dt (6) 81 (6)
Three-phase thermal protection for feeders, cables
and distribution transformers
T1PTTR1 3Ith>F 49F
Three-phase thermal overload protection for power
transformers, two time constants
T2PTTR1 3Ith>T 49T
Table continues on next page
1YHT530004D05 D Section 1
Introduction
615 series 29
Technical Manual