Functionality................................................................................71
Fault records.....................................................................................73
Non-volatile memory.........................................................................77
Binary input.......................................................................................78
Binary input filter time..................................................................78
Binary input inversion..................................................................79
Oscillation suppression................................................................79
Binary outputs...................................................................................79
Power output contacts ................................................................80
Dual single-pole power outputs PO1 and PO2.......................80
Double-pole power outputs PO3 and PO4 with trip
circuit supervision...................................................................81
Dual single-pole high-speed power outputs HSO1,
HSO2 and HSO3....................................................................82
Signal output contacts ................................................................83
Internal fault signal output IRF ..............................................83
Signal outputs SO1 and SO2 in power supply module..........84
Signal outputs SO1, SO2, SO3 and SO4 in BIO0005............84
Signal outputs SO1, SO2 and SO3 in BIO0006.....................85
RTD/mA inputs ................................................................................86
Functionality................................................................................86
Operation principle......................................................................86
Selection of input signal type..................................................86
Selection of output value format.............................................87
Input linear scaling.................................................................87
Measurement chain supervision.............................................88
Selfsupervision.......................................................................88
Calibration..............................................................................89
Limit value supervision...........................................................89
Deadband supervision............................................................90
RTD temperature vs. resistance.............................................91
RTD/mA input connection......................................................92
Signals.........................................................................................94
Settings........................................................................................94
GOOSE function blocks....................................................................97
GOOSERCV_BIN function block.................................................97
Function block........................................................................97
Functionality...........................................................................98
Signals....................................................................................98
GOOSERCV_DP function block..................................................98
Function block........................................................................98
Functionality...........................................................................98
Signals....................................................................................98
GOOSERCV_MV function block..................................................99
Table of contents
2 615 series
Technical Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB REF615 L and is the answer not in the manual?

ABB REF615 L Specifications

General IconGeneral
TypeFeeder Protection Relay
Rated Frequency50/60 Hz
WeightApprox. 1.5 kg
Communication ProtocolsIEC 61850, Modbus RTU, DNP3
Protection FunctionsOvercurrent, Earth fault, Thermal overload, Under/Over voltage, Under/Over frequency
EnclosureIP20