Section 11 – History Log
11-5
History Log Alpha and Event Codes
Description Alpha ADEMCO
CID
System Event
System Reset RESET
Reset Memory RESET MEM
AC Fail AC FAIL 301
AC Restore AC RESTORE 301
AC Fail 4-Hour AC FAIL 4H 926
AC Fail 4-Hour Restore AC 4H RST 926
Telco Line Trouble (Line 1 or Line 2) TELCO TBL 350
Telco Line Trouble Restore (Line 1 or Line 2) TELCO RST 350
Low Battery System LOW BAT 302
Low Battery System Restore BATTERY RS 302
Change Date CH DATE
Expansion Module
Interactive Keypad Tamper KEYPAD ALM 143
Interactive Keypad Trouble supervision
KEYPAD TBL 333
Interactive Keypad Trouble Restore KEYPAD RST 143
Cardreader Alarm READER ALM 143
Cardreader Trouble READER TBL 333
Cardreader Trouble Restore READER RST 143
Point Gateway Tamper Alarm GATEWAY AL 143
Point Gateway Trouble supervision
GATEWAY TB 333
Point Gateway Trouble Restore GATEWAY RS 143
Printer Tamper Alarm PRINTER AL 336
Printer Trouble – Supervision PRINT TBL 333
Printer Trouble Restore PRINT RST 336
RF Low Battery RF LOW BAT 384
RF Point Low Battery Restore RF LB RST 384
Downloading
DLL Aborted DLL ABORT 900
Start DLL START DLL 901
DLL Interrupted DLL INTER 902
End DLL Altered END DLL AL 412
DLL Comm Fail DLL COMM F 413
End DLL Not Altered END DLL NA 901
Burglary
BA Burglary Alarm BURGLAR AL 130
BA Burglary Point Bypass BA BYPASS 573
BA Burglary Alarm Restore BURGLAR RS 130
BA Burglary Point Trouble BURGLAR TB 380
BA Burglary Point Unbypass BA UNBYP 573
Open/Close
BA Auto Close AUTO CLOSE 403
BA Auto Close with Bypass – within Group AUTO CL BY 910
BA Trouble Closing (closed with burglary alarm during exit) TBL CLOSE 920
BA Bypass Closing – within group BYP CLOSE 911

Table of Contents

Other manuals for ADT Focus 200 Plus