Section 22 – Equipment
22-5
148320 Trunk Junction Box
A small white plastic junction box for dressing up the trunk-to-branch cable splices. Snaps over wire
and Scotchlok connectors. Made of a flame-retardant poly-propylene and designed to be used in a
plenum.
370320 Junction Box (7032)
A small gray plastic junction box for housing the stand-alone SIM module when making connections to
a sensor, and for general wire splices.
809190 Connector
Scotchlok #558 electrical connector (T-tap type). Used for solid and stranded wires of 16 to 22 AWO. UL
approved. Supplied in a box of 100.
304662 Ground Clamp (B466)
A clamp that is attached to a 3/4" to 1-1/2" cold-water pipe for CWG connection.
148227 Ground Clamp
A clamp that is attached to a 1/2" to 1" cold-water pipe for CWG connection.
148230 Tag
A tag for attaching to a ground clamp warning subscriber not to remove clamp.
SIM Sensors
472370 FA Pull Station (w/SIM)
Manual FA Pull Box similar to a 455301(5060-S) except has a built-in SIM. It is a dual-action, single-
stage device with keyed reset. Semi-flush mounts in single-gang switchbox (purchased locally) or
surface mounts in 144910 Backbox. May also require 144917 Backplate or 146064 Break Rod, each of
which is listed in T-7 187 FOCUS System Common Equipment Technical Data sheet. Communicates
with a 472368 SIM Gateway via two-wire connection.
AI
=
SI
=1mA
472374 Holdup Alarm Switch (W/SIM)
A finger-operated holdup device similar to a 441494 (6913-002) Holdup Alarm Switch, except it has a
built-in SIM. It is a dual-action latching device that requires user to insert a finger and then pull to
activate a holdup alarm. Includes 441495 Reset Tool, which must be used to restore switch to normal
condition. Also includes mounting hardware and a 11’ (3.4m) captive cable. Communicates with a
472368 SIM gateway via two-wire connection. Al=
SI
=1mA
472488 Supervised Horn/Strobe SIM
A stand-alone SIM for interfacing various types of horn/strobes (that are not already equipped with a
SIM) to the SIM Gateway. Current of horn or strobe must be less than 300mA each. Also used for
controlling an output function where the +12V output must be supervised. Comes with 6" flying leads
for making horn/strobe connections. Horn/Strobe SIM can be installed in the horn backbox or in a
separately ordered 370320 (7032) Junction Box.
AI
=
SI
=3mA
472420 Horn Strobe
A Wheelock surface-mount or flush-mount 101/94db (horn/bell) white horn unit with a front-mounted
15Cd, 1Hz, UL1971 approved strobe light. A white 472421 backbox is available for surface mounting.
May also be flush mounted directly to sheetrock through a 3.25" W x 2.75" H rectangular hole.
Controlled and powered via a 472388 Horn/Strobe SIM. Strobe + Horn Mode AI=260mA, SI=0mA
Strobe + Bell Mode Al=190mA, SI=0mA

Table of Contents

Other manuals for ADT Focus 200 Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Focus 200 Plus and is the answer not in the manual?

ADT Focus 200 Plus Specifications

General IconGeneral
BrandADT
ModelFocus 200 Plus
CategorySecurity System
LanguageEnglish

Related product manuals