FOCUS 200 PLUS Installation and Setup Guide
5-24
RF Gateway Physical Description
The gateway consists of a printed wiring board that is installed in a plastic housing unit. The following
are important items on the board (see
Figure 5-16)
:
Part Purpose
Terminal Strip TB1 Used for making connections to the RS-485 bus, to the RF receiver, and to
power the RF gateway.
Panel LED (red)
Indicates the following
status:
Steady OFF:
No communication/activity between the control panel and the
RF gateway.
Flashing:
Normal condition.
Steady ON:
The RF gateway is in an error state.
RF LED (green) Indicates the following status:
Steady OFF:
The RF gateway is in an error state or is receiving no power.
Flashing:
Normal condition.
Steady ON:
Power indication for the RF gateway. No RF transmission
activity, or receiver(s) have failed, or the receiver’s antenna has
a problem.
6
5
4
3
2
1
(+)
12V
(–)
GND
H BUS
(+)
H BUS
(–)
DATA INPUT
DATA OUTPUT
5800ADT RF EXPANDER MODULE
PANEL LED (RED)
RF LED (GREEN)
5800ADT
TB1
I
O
+
+
–
–
6
5
4
3
2
1
(
+)
12V
(
+)
12V
(–)
GND
(–)
GND
H BUS
(+)
(+)
H BUS
(–)
(–)
DATA INPUT
DATA OUTPUT
CONNECT TO
5881H/5881EH/5882H
RF RECEIVER
TO
CONTROL PANEL
G
R
E
E
N
B
L
A
C
K
Y
E
L
L
O
W
R
E
D
TB1
I
O
+
+
–
–
5800ADT
TERMINALS
P1
ECP
BUS
RS485
BUS
BLACK
YELLOW
BLUE
RED
CONNECTOR
Figure 5-16: RF Gateway Wiring Connections
Installing the RF Gateway
Mounting the RF Gateway
To mount the RF gateway, perform the following steps:
Step Action
1
Remove the RF gateway’s circuit board from its plastic case and mount the case with the
appropriate mounting hardware.
2 Re-insert the circuit board into the plastic case.