Section 21 – Specifications
21-3
RF Gateway
Dimensions 4.25” H x 6.44” W x 1.25” D
Temperature Range 32
°
F (0
°
C) to 120
°
F (49
°
C)
Gateway Circuit Power Requirement 50mA
Worst Case Voltage @ Gateway 12.1VDC
(End of Standby Period) 8.4VDC
Tamper
Control Unit Cover included (pry-off kit available for UL listing)
SIM Gateway Cover
PID Gateway Cover (ordered separately)
Operating Panel Cover and pry-off
Printer Interface Unit Cover and pry-off
Approvals
The FOCUS 200 PLUS System has been approved by the following agencies for listing:
Underwriters Laboratories Inc. (UL)
Federal Communications Commission (FCC)
Factory Mutual (FM)
California State Fire Marshall
Underwriters Laboratories of Canada (ULC)
The FOCUS 200 PLUS System complies with UL609, UL611, UL864, UL985, UL1023, UL1610,
UL1635, NFPA71, and NFPA72, and will be submitted for approval to various European agencies.
Access Control Interface Unit
Electrical/Mechanical Specifications
The 472270 Access Control Interface Unit is designed to meet the following specifications:
Size 7-1/4" x 4-1/4" (18.4cm x 10.8cm)
Housing 472852 Housing Unit
Operating temperature range 32
°
F (0
°
C) to 120
°
F (49
°
C).
Power required 12.5VDC @ 60mA (includes float charge for standby battery)
Nominal operating voltage 12VDC
(End of Standby Period) 8.5VDC
Standby battery 12VDC, 0.8AH
Max. cable distance to reader/strike 150 feet
Max. current to strike 550mA
Approvals for the ACIU
The Access Control Interface Unit has been approved by the following agencies for listing:
Underwriters laboratories Inc. (UL)
Federal Communications Commission (FCC)
Factory Mutual (FM)
California State Fire Marshall
Underwriters Laboratories of Canada (ULC)
The FOCUS 200 PLUS System complies with UL294 (Access), UL864 (Fire), UL1635 (DACT), UL1076
(Proprietary), UL1610 (CCC), and NFPA72, and will be submitted to various European agencies.

Table of Contents

Other manuals for ADT Focus 200 Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Focus 200 Plus and is the answer not in the manual?

ADT Focus 200 Plus Specifications

General IconGeneral
BrandADT
ModelFocus 200 Plus
CategorySecurity System
LanguageEnglish

Related product manuals