EasyManua.ls Logo

ADT Focus 200 Plus - Page 162

ADT Focus 200 Plus
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FOCUS 200 PLUS Installation and Setup Guide
15-6
Close Time Reminder and Warning
The Close Time Reminder and Close Time Warning periods occur at the end of the Close Time Timer
countdown.
During the Close Time Reminder, the operating panel beeps once a minute. This serves to alert the
user to get ready to close because the closing time is about to end.
At the end of the Close Time Reminder, the Close Time Warning begins. During this time, the
operating panel sounds a continuous tone. This serves to alert the user that the close time has ended
and a No Close signal is about to be transmitted to the CCC unless the BA group is turned on before
the warning time ends.
The duration of the Close Time Reminder and Close Time Warning is programmed in the No Close
option. The choices are:
15 minutes for the Close Time Reminder and 15 minutes for the Close Time Warning.
30 minutes for the Close Time Reminder and 5 minutes for the Close Time Warning.

Table of Contents

Other manuals for ADT Focus 200 Plus

Related product manuals