FOCUS 200 PLUS Installation and Setup Guide
22-2
472404 Transformer
18VAC/72VA wired-in transformer, which may be required for some commercial fire installations.
VISTA-ULAP Attack Proof Kit
Hardware kit required for UL-certified burglary installations.
471210 Operating Panel
Controls all operations of the FOCUS 200 PLUS System; can be used to control all or any combination
of the eight BA groups. Panel is interactive and features a four-line LCD screen and an alphanumeric
keypad. Panel measures 8"w x 4-1/2" H x 1-1/2" D and is normally surface mounted. The keypad can
optionally be mounted on a desk, with a 472382 Desk Stand; or angle wall-mounted, using a 148248
Angle Bracket. The unit may be protected from damage using an STI Model 6550 Widebody Keypad
Protector. Up to 16 keypads may be used with the FOCUS 200 PLUS system.
AI
=65mA,
SI
=32mA
472368 SIM Gateway
For accommodating up to 72 SIM input/output points. Consists of a tampered circuit board that is
housed in a separately ordered 471943 Housing Unit (same as for Micro PID). Gateway comes with two
terminal strips: one for connection to the RS-485 bus and one for connecting the gateway trunk,both of
which use 494465 (B6465) Cable.
AI
=
SI
=50mA
472366 Sensor Interface Module (SIM)
For interfacing any sensor (that is not already equipped with a SIM) to the SIM Gateway. Also used for
controlling an output function (via + 12V output). Comes with 6" flying leads for marking connections
and a 869706 End-of-Line Resistor (33K ohm, 5%, 1/2W). If SIM cannot be installed in associated
device, it must be installed in a separately ordered 370320 (7032) Junction Box.
AI
=
SI
=1mA
For information on sensors with built-in SIM, see SIM Sensors later in this section.
248239 PID Gateway
For accommodating up to 62 PID points. Consists of a circuit board that is housed in a separately
ordered 472352 Housing Unit (standard white PID box). Gateway comes with one terminal strip for the
connection to the RS-485 bus and two terminal strips for connecting a quad trunk, all of which use
494465 Cable. A 248116 Tamper Kit can be ordered separately.
AI
=
SI
=50mA
472490 RF Gateway
Consists of a 5800ADT RF Gateway Module and one (1) 5881H RF Receiver. One (1) additional 5881H
RF Receiver may be added to improve reception. RF Gateway -
AI
=
SI
=50mA
RF Receiver -
AI
=
SI
=60mA
472491 AC Communicator Module
Used to report signals to a monitoring station using either AC telephone lines, DC telephone lines or
RS-232.
AI
=
SI
=250mA
472402A Backup Dialer
Provides an alternate means of communication to the CCC that may be required for some commercial
fire installations
AI
=15mA,
SI
=5mA
472425 LIM (Loop Interface Module)
The LIM connects to the trunk of a SIM loop and it functions like a SIM, but it employs a 2-wire
protection loop that is supervised for grounds. Consequently, it can be used for retrofit applications
involving sensors connected to a 2-wire loop, fire alarm applications that require a ground-supervised
loop, and other applications in which a SIM cannot be used for one reason or another.
472430 RS-485 Repeater
The repeater serves as a signal regenerator that can extend the reach of a FOCUS control unit RS-485
bus up to 4000 feet for a single run. Additionally, it can be used for T-tapping the RS-485 bus.

Table of Contents

Other manuals for ADT Focus 200 Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Focus 200 Plus and is the answer not in the manual?

ADT Focus 200 Plus Specifications

General IconGeneral
BrandADT
ModelFocus 200 Plus
CategorySecurity System
LanguageEnglish

Related product manuals