5702269-C I/O Communication and Control 4-87
Pinnacle™ Plus+ 10 kW
163
request
config status
(continued
from previous
page)
3rd status byte:
• 0 = Synch pulse setting
(0 = receiver, 1 = transmitter)
• 1 = Over-voltage timer active
• 2 = Over-current timer active
• 3 = Constant duty cycle active
• 4 = Micro arc handling
(0 = disabled, 1 = enabled)
• 5 = Pulsing enabled
(0 = at current threshold, 1 = always)
• 6 and 7 = Threshold type
(00 = power, 01 = voltage, 10 = current)
4th status byte:
• 0 = Hard-arc broadcast
(0 = disabled, 1 = enabled)
• 1 = Joule countdown hold
(0 = disabled, 1 = enabled)
• 2 through 7 = Unassigned
04
164
request set
point/
regulation
mode
Requests the set point level by whichever
method of output regulation has been selected;
the returning packet contains 3 data bytes:
• First/second byte = Set point level
(16-bit value)
• Third data byte = Regulation mode
(8-bit value)
4
6 = Power
4
7 = Voltage
4
8 = Current
Note: Output power must be off (that is, output
must be deenergized) to switch between
regulation modes.
These values are set with commands 3 and 6.
03
Table 4-19. AE Bus Commands (Continued)
Command Description Number
of
Transmit
Data
Bytes
CSR
Codes or
Number of
Response
Bytes