5702269-C I/O Communication and Control 4-29
Pinnacle™ Plus+ 10 kW
5. To display the software version of the DSP software, press DSP.
6. To display the software version of the logic, press LOGIC.
USING THE SUPPLY FUNCTIONS
This option lets you modify specific components and parameters of your supply. The
menu options are:
•AEBUS:
• DEFAULTS:
•PULSE:
• PANEL:
• PGM_SRC:
Setting the AE Bus Timeout
SUPPLY → AE BUS
To set your AE Bus timeout time:
1. Press SUPPLY → AEBUS.
2. Rotate the MODIFY knob to adjust the AE Bus time out value (in 10 ms
increments).
3. Press ENTER to accept and exit.
Note: We recommend you use the default value of 200 ms.
Setting the Supply Parameters
SUPPLY → DEFAULTS
To set all your supply parameters to the defaults and then store them in non-
volatile memory:
1. Press SUPPLY → DEFAULTS.
2. Rotate the MODIFY knob to display YES or NO.
3. Press ENTER to accept and exit.
Setting Pulse Parameters
SUPPLY → PULSE