5702269-C I/O Communication and Control 4-37
Pinnacle™ Plus+ 10 kW
has priority. If a change to the target is attempted on the front panel, “User
Port Has PRIORITY” displays, and you must depress the MODIFY knob
to exit (ENTER is no longer displayed).
PROCESS MONITORTARGET LIFE
To set the target life in 0.01 kWh increments:
1. Press PROCESS MONITOR TARGET LIFE.
2. Rotate the MODIFY knob to select a target life between 0 and 15000.00 kWh
(The default is 0).
4
If you are rotating the MODIFY knob slowly, press the appropriate soft key to
indicate how quickly you want the display to increment the value (x1000, x100,
x10 or x1). Note: If you turn the MODIFY knob quickly, the counts per click
setting takes effect.
3. Press ENTER to accept and exit.
This function will also display how much target life is left as the counter decreases.
When the end-of-target-life is reached, the output display screen flashes “EOTL” and
the Pinnacle Plus+ unit continues running until a normal off command is received.
Note: The Pinnacle Plus+ unit cannot turn back on until the target life is reset or
until the target status is disabled or a new active target is selected.
Setting Process Limits
PROCESS LIMITS
This menu lets you control user-selectable operating limits for the Pinnacle Plus+ unit:
maximum output (voltage, current, and power).
Note: Before entering a maximum output limit, consider your system's output
impedance and consider how your selected power limits will interact. The unit
will limit output when output reaches the first applicable limit.
Note: You cannot set a set point greater than the corresponding limit in that regulation
mode.
SETTING A MAXIMUM LIMIT FOR OUTPUT VOLTAGE
PROCESS LIMITS VOLTAGE
This function lets you set a maximum limit for output voltage as measured at the DC
inverter output (see Figure 2-1 on page 2-2). The maximum allowable value is the
maximum rated output for the supply.
To set the user voltage limit:
1. Press PROCESS LIMITS VOLTAGE.