5702269-C I/O Communication and Control 4-19
Pinnacle™ Plus+ 10 kW
To control the Pinnacle Plus+ supply from a serial interface or the DeviceNet port,
press the CONTROL key until the HOST LED lights. To control the Pinnacle Plus+
supply from the User port, press the CONTROL key until the USER LED lights.
When the Pinnacle Plus+ unit is in host or user control mode, you can view all the
menu items, but you cannot modify parameters or lock the display.
Note: You can not change control modes while output power is energized (on).
Regulation Key
Use this key to select the method of output regulation when the control panel has
control (local control).
Note: You can not change regulation modes while output power is energized (on).
Two-Line Output Display Screen
The display screen displays two lines of information. When you first power up, the
display screen appears.
Table 4-10. Control Key LEDs
LOCAL
Specifies that control of the Pinnacle Plus+ power supply has
been assigned to the control panel.
HOST
Specifies that control of the Pinnacle Plus+ power supply has
been assigned to a serial interface (that is, Host port,
DeviceNet port, or standard serial port).
USER
Specifies that control of the Pinnacle Plus+ power supply has
been assigned to the User port.
Note: User control can only be selected when a User port
interface card is installed in the unit.
Table 4-11. Regulation Key LEDs
POWER
Specifies that the method of output regulation is power.
CURRENT
Specifies that the method of output regulation is current.
VOLTAGE
Specifies that the method of output regulation is voltage.