HIGH SPEED AEBUS: Changes the baud rates; requires a power cycle on the unit
before the change takes effect. The following are the baud rates when HIGH SPEED
AEBUS is disabled or enabled:
EXPLICIT FAULT CLEARING: Changes the fault clearing method; changes
immediately. When method is set to DISABLED, power must be cycled on the unit to
clear the fault. When method is set to ENABLED, the OFF or RESET command will
clear the fault.
Checking Your ROM
SERVICE → MEMORY
To perform ROM cyclic redundancy check (CRC) checking:
Note: There is a momentary delay before the CRC will display.
Note: Not all cards support this option.
1. Press SERVICE → MEMORY → ROM → CARD.
2. To calculate and display the active panel (local or remote) CRC, press PANEL.
3. To calculate and display the DSP CRC, press DSP.
4. To calculate and display the logic board CRC, press LOGIC.
Checking Your Software Versions
SERVICE → SW_REV
To find out the software number and version of your system software
components:
1. Press SERVICE → SW_REV.
2. To display the software version of the configuration, press CONFIG.
3. To display the software version of the cards installed in your unit, press CARD.
4. To display the software version of the active panel software, press PANEL.
Table 4-12. Baud Rates When HIGH SPEED AEBUS is Disabled/Enabled
Disabled Enabled (Same for RS232/422/485)
1200 19200
4800 38400
9600 57600
19200 115200