5702269-C Specifications 3-1
Chapter
Pinnacle™ Plus+ 10 kW
Chapter
3
Specifications
FUNCTIONAL SPECIFICATIONS
Table 3-1. Functional Specifications
Modes of Control
Serial communications (Host) port, User port
(analog/digital interface), active front panel, and/
or Pinnacle Remote Active Panel
Passive Panel Options
Your unit also may feature either a passive front
panel, remote active panel, blank panel, or an
active front panel.
Method of Output
Regulation
The regulation mode is the parameter that remains
constant when the Pinnacle Plus+ is producing
output; it can be power, or current, or voltage.
Select one of these regulation modes from the
optional Pinnacle Remote Active Panel, the active
front panel, the User port, or the serial (Host) port.
Note: Output power must be off (that is, output
must be deenergized) to switch between
regulation modes.
Programmable Set
Points
You can program an output level (from low values
up to the unit's maximum rate of output) for
power, current, or voltage. You can also program
the chopper output frequency and reverse time.
Select these values from the optional Pinnacle
Remote Active Panel, the active front panel, the
User port, or the serial (Host) port.
Note: The User port does not have access to the
chopper.
Output Limits
You may set maximum output limits for power,
voltage, and current. Select these values from the
optional Pinnacle Remote Active Panel, the active
front panel, or the serial (Host) port.
Process Control
You can control the process with the following
features: joule mode, ramping, and recipes.