2. Rotate the MODIFY knob to select a value between 0 and the maximum rated
output voltage for the supply.
3. Press ENTER to accept and exit.
SETTING THE MAXIMUM LIMIT FOR OUTPUT CURRENT
PROCESS → LIMITS → CURRENT
This function lets you set a maximum limit for output current. The maximum
allowable value is the maximum rated output for the supply.
To set the user current limit:
1. Press PROCESS → LIMITS → CURRENT.
2. Rotate the MODIFY knob to select a value between 0 and the maximum rated
output current for the supply.
3. Press ENTER to accept and exit.
SETTING THE MAXIMUM LIMIT FOR OUTPUT POWER
PROCESS → LIMITS → POWER
This function lets you set a maximum limit for output power. The maximum allowable
value is the maximum rated output for the supply.
To set the user power limit:
1. Press PROCESS → LIMITS → POWER.
2. Rotate the MODIFY knob to select a value between 0 and the maximum rated
output power.
3. Press ENTER to accept and exit.
Setting Arc Handling
PROCESS → ARC
Use the ARC menu to implement arc-handling during your normal process cycle or
during standby. Selections in the ARC menu let you establish arc-handling parameters
for normal process runs. In addition, the PROCESS menu lets you view arc density
statistics.
SETTING THE VOLTAGE ARC TRIP LEVEL
PROCESS → ΑRC → LEVEL