5702269-C I/O Communication and Control 4-27
Pinnacle™ Plus+ 10 kW
CHECKING YOUR HARDWARE CONFIGURATION
SERVICE → DEBUG → HW CONFIG
To find out whether or not a card is installed in slot 1 or 2:
1. Press SERVICE → DEBUG → HW CONFIG.
4
A report of the personality cards installed in the supply in slot 1 and slot 2
appears.
CHECKING YOUR COMMUNICATIONS CARD
SERVICE → DEBUG → CARD
Use this option to find out specific communications debug information:
1. Press SERVICE → DEBUG → CARD.
Note: Not all cards support this feature.
CHECKING YOUR SOFTWARE LOGIC
SERVICE → DEBUG → LOGIC
Use this option to find out what software logic options are installed.
1. Press SERVICE → DEBUG → LOGIC.
4
The configuration options display one at a time. Arrows above the first two soft
keys allow you to move forward or backward. Selections that can be changed
will appear with CHANGE on the 4th soft key. ENTER is on the 5th soft key
in all cases.
2. Use the arrow keys to move to the selection you want.
3. Press the 4th soft key (CHANGE) to select the change, and then press the 5th soft
key (ENTER). The change is accepted and you are returned to the Service_Debug
level.
Note: Pressing the knob also returns you to the Service_Debug level, but the
change is not saved.
The following are the available configuration options. Note that certain configuration
options are reset immediately, while others require cycling power on the unit.
RAMP RESOLUTION: 10ms to 100ms; changes immediately.
JOULE RECIPE STATUS: Redefine the Profibus upload status bits; changes
immediately.
USER-PORT EOTL DEFINED AS: Changes the definition form indicating End of
Target Life (EOTL) or a ready signal; changes immediately.