4-36 I/O Communication and Control 5702269-C
Advanced Energy
®
Out-of-Set Point Tolerance Range = Set point ±0.4% of full scale or 2% of set point,
whichever is greater.
When an out-of-set point condition occurs, the unit shuts off output and displays error
code E001. (See the “Error Codes” section of the “Troubleshooting” chapter for more
information about error codes).
To enable the out-of-set point timer, follow these steps to select a value (in 0.1 s
increments). To disable the timer, follow these steps and select a value of 0.
Note: Because the readbacks, which are compared to the set point, are filtered in the
software, we recommend you do not use this feature for process runs that are
less than 1 s.
1. Press PROCESS MONITORSETPT.
2. Rotate the MODIFY knob to adjust the value.
3. Press ENTER to accept and exit.
CHANGING THE TARGET FUNCTIONS
PROCESS MONITORTARGET
The target functions let you enable or disable the target life counter (ENABLE),
change the active target (SELECT), and set the target life (LIFE) in 0.01 KWh
increments.
PROCESS MONITORTARGET ENABLE
To enable or disable the target life counter for the selected target:
1. Press PROCESS MONITOR TARGET ENABLE.
2. Rotate the Modify knob to select YES or NO.
3. Press ENTER to accept and exit.
PROCESS MONITORTARGET SELECT
To change the active target life counter:
1. Press PROCESS MONITOR TARGET SELECT.
2. Rotate the MODIFY knob to select the active target number.
3. Press ENTER to accept and exit.
Note: The User port has priority in selecting targets. Thus, if your unit has a user
card installed, you must set the target to 1 at the User port if you want to
select targets from the serial port, active front panel, or Pinnacle Remote
Active Panel (that is, when the Pinnacle Plus+ unit is in host or local
control mode). Leaving the target bits open or leaving the User port pins
unconnected causes the target selection at the User port to default to 1.
When the User port is set to a target other than 1, the User port selection