5702269-C Installation 5-15
Pinnacle™ Plus+ 10 kW
2. If the Pinnacle Plus+ supply includes a User card, ensure that the interlock inputs
are satisfied. Refer to the “I/O Communication and Control” chapter for specific
User port pin descriptions and required voltage levels.
3. Set the MSTR/SLV switch (see Figure 5-7) in the "up" (MSTR) position.
4. Connect the included master/slave interface cable (with the modular plug ends)
between port P1 (the MSTR port) on the master unit and port P2 (the SLV port)
on the first slave unit.
Note: The master unit will not have an interface cable connected to port P2.
5. Connect the included master/slave pulse interface cable (with the 15-pin,
subminiature-D plug ends) between the port labeled (Master/Slave Pulse) on the
master unit and the port labeled (Master/Slave Pulse) on all associated slave units.
6. Use a grounding strap to connect an equi-potential ground stud on the master unit
to an equi-potential ground stud on the first slave unit.
To configure a master unit as a stand-alone unit, do the following:
1. Set the MSTR/SLV switch in the "up" (MSTR) position.
2. Remove all Master/Slave interface cables from the master unit.
Configuring Your Slave Units
To configure a slave unit:
Note: See Figure 5-10 on page 5-16 for an illustration.
1. Remove input power from the master and slave units.
2. If the Pinnacle Plus+ supply includes a User card, ensure that the interlock inputs
are satisfied. Refer to the “I/O Communication and Control” chapter for specific
User port pin descriptions and required voltage levels.
3. Set the MSTR/SLV switch (see Figure 5-7) in the "down" (SLV) position.
4. Connect the included master/slave interface cable (with the modular plug ends)
between port P1 on the first slave unit and port P2 on the next slave unit. Continue
cabling slave units together in this daisy-chain manner.
Note: The last slave unit on your system will not have an interface cable
connected to port P1.
5. Connect the included master/slave pulse interface cable (with the 15-pin,
subminiature-D plug ends) between the port labeled (Master/Slave Pulse) on the
master unit and the port labeled (Master/Slave Pulse) on all associated slave units.
6. Use a grounding strap to connect an equi-potential ground stud on the first slave
unit to an equi-potential ground stud of the next slave unit. Continue connecting
together subsequent slave unit chassis in this manner. We recommend you
connect the ground stud on the master unit to system ground.
Page 161 of 204