EasyManuals Logo

Aeon COBRA 400 2012 User Manual

Aeon COBRA 400 2012
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
MAINTENANCE
2-14
2. Remove spark plug and rotate engine to TDC on the
compression stroke. There are 2 places align TDC, One locates
in engine oil filling cap of upper right crankcase, another locate
at in inspection cover of right cylinder dead.
3. Insert a 0.1 mm feeler gauge between end of intake
valve stem
and adjuster screw.
4. If adjustment is required, loosen the locknut and turn
adjuster
until the proper clearance is obtained.
5. When clearance is correct, hold adjuster screw and tighten
locknut securely.
6. Re-check the valve clearance.
7. Repeat steps 3-5 to adjust the exhaust valve clearance.
Valve Clearance
In: 0.1 mm
Ex: 0.12 mm
ENGINE MOUNTS LOCATION
Inspect engine mounts for cracks or damage.
Front-
Rear-
Engine Fastener Torque
Check engine fasteners and ensure they are tight.
Engine Mount Torque Value: 40 Nm (30 ft. lbs.)