86 Software
4510001 REV B – 220620
PLC Output 1 and 2 Screens
The PLC Output Screens indicate an output error for the component listed.
Output Refers to Meaning
Y0 Cutter “Pulse-”
Pulse output to operate the
Cutter Servo
: Currently triggered/activated
⬜: Not currently triggered/activated
Y1 Cutter “Dir-”
Output to define the Cutter
Servo direction
: Currently triggered/activated
⬜: Not currently triggered/activated
Y2 Feed “Pulse-”
Pulse output to operate the
Film Feed Servo
: Currently triggered/activated
⬜: Not currently triggered/activated
Y3 Feed “Dir-”
Output to define the Film
Feed Servo direction
: Currently triggered/activated
⬜: Not currently triggered/activated
Y4 Working (RY1)
Output to turn on Relay 1
(for the Applicating Motor)
: Currently triggered/activated
⬜: Not currently triggered/activated
Y5 Buzzer (RY2)
Output to turn on Relay 2
(for the Buzzer)
: Currently triggered/activated
⬜: Not currently triggered/activated
Y6
Print Function Use
(Stop Feed)
Output to the Film Feed
Servo
: Currently triggered/activated
⬜: Not currently triggered/activated
Y7 Brush
Output to turn on Relay 3
(for the Brushdown
Assemblies)
: Currently triggered/activated
⬜: Not currently triggered/activated
Y8
Tower Light – Yellow
(RY4)
Output to turn on Relay 4
(for the yellow Beacon
Light)
: Currently triggered/activated
⬜: Not currently triggered/activated
Y9
Film Supply Motor
(RY5)
Output to turn on Relay 5
(for the UR-1 Unwind)
: Currently triggered/activated
⬜: Not currently triggered/activated
YA
Timing Screw Motor
(RY6)
Output to turn on Relay 6
(for the Timing Screw
Motor)
: Currently triggered/activated
⬜: Not currently triggered/activated