Information Meaning
Lucent Compatibility Byte The Compatibility byte is a positive integer
between 0 and 255 containing a code that
represents the Alcatel-Lucent system(s) for which
the SFP is intended.
Only the number is displayed on the user
interface:
16 or 17 is used for AMS,
32 or 33 is used for DMX,
64 or 65 is used for Metropolis ADM
(Universal Shelf) and
128 or 129 is used for Lambda Unite.
Lucent Unique ID A 4 byte HEX field.
SFP Vendor ID A 4 byte character string.(20HEX). Represents
the Manufacture Location Code of the
Alcatel-Lucent Serial Number, which is as WES
code also represented on the label of the SFP.
WES Serial Number An 18 byte character string. SFP’s. Represents
the Alcatel-Lucent specific Serial Number, which
is as WES code (18 Byte) also represented on
the label of the SFP.
Module Qualifier Derived from SFP SEEPROM information.
1000BASE-SX
1000BASE-LX
I-1
S-1.1
L-1.1
L-1.2
L-1.3
I-4
S-4.1
L-4.1
L-4.2
L-4.3
{
Equipment provisioning
Parameters for viewing SFP inventory data
....................................................................................................................................................................................................................................
5-44