Result: The Performance Monitoring Point Filter window appears.
...................................................................................................................................................................................................
4
Select LAN for PM Point Type and select the Port and then click Ok.
Result: The Edit Performance Monitoring Point window appears.
...................................................................................................................................................................................................
5
Select the measurement period by clicking either Unidir 15 Min or Unidir 24 hr tab
and then enable the counters by marking the Enable Counters check box.
Result: The checkbox Enable Counters is enabled.
...................................................................................................................................................................................................
6
Enable thresholding by marking the Enable Thresholding checkbox.
Result: The threshold crossing functionality is enabled. The systems retrieves the
last saved TR and RTR values from the NE and reports it in each parameter field.
If there is no previously saved TR and RTR values (as for a new termination
point), the system will fill in the default threshold values for those parameters (for
thresholds range, minimum/maximum, and default values, see “Concepts” (p. 10-3).
...................................................................................................................................................................................................
7
Select OK.
Result: The Edit Performance Monitoring Point Filter window disappears. The
Active Performance Monitoring Points window gets dynamically updated if they
are opened.
...................................................................................................................................................................................................
8
Select Performance -> PM Current Measurements.
Result: The Select Performance Monitoring Points window is displayed. The
ITM-CIT is in measurement mode.
...................................................................................................................................................................................................
9
Click Ok.
Result: The Current Performance Monitoring Measurement window is displayed
along with the Port monitor counters.
E ND OF STEPS
...................................................................................................................................................................................................
Performance monitoring
General Purpose Ethernet Port Monitor
....................................................................................................................................................................................................................................
10-60
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2
Issue 4, May 2007