Perform a one-time round trip delay measurement for test
purposes
...................................................................................................................................................................................................................................
When to use
This procedure is used to perform a one-time round trip delay measurement to a
remote NE.
Note: The Perform a one-time round trip delay measurement for test purposes
procedure is also applicable to X5IP.
Related information
The items below list other relevant information to this procedure:
“Ethernet service route round trip delay measurements” (p. 10-23)
Before you begin
The items below gives information on tasks to perform before beginning the procedure:
“Provisioning a virtual switch in spanning tree mode” (p. 8-105)
“Enable round trip delay measurements” (p. 10-69)
Procedure
...................................................................................................................................................................................................
1
Select the Ethernet Service Route in the Round Trip Delay Measurement window and
click
Test.
Result: The RTD Test window appears.
...................................................................................................................................................................................................
2
Click Trigger.
Result: A message will appear on the screen with the lines: 15 seconds is needed
to finish this test. Are you sure you wish to trigger a one shot RTD measurement?
...................................................................................................................................................................................................
3
Click Yes.
Result: The RTD Value and Success Indication will be displayed in the RTD Test
window.
...................................................................................................................................................................................................
4
Click Close.
E ND OF STEPS
...................................................................................................................................................................................................