3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-119
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Name: SectionLossOfSignal
Type: communicationsAlarm (4)
Probable cause: sectionLossOfSignal (77)
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a SLOS error. The alarm
corresponds to the slos alarm on an
NE.
Name: SectionS1Failure
Type: communicationsAlarm (4)
Probable cause: sectionS1Failure (72)
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a section
synchronization failure. A section
synchronization failure occurs when
the S1 byte is inconsistent for eight
consecutive frames.
Name: SonetPathAlarmIndicationSignal
Type: communicationsAlarm (4)
Probable cause: pathAlarmIndicationSignal
(63)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a PAIS error. The alarm
corresponds to the pais alarm on an
NE.
Name: SonetPathB3Error
Type: communicationsAlarm (4)
Probable cause: pathB3Error (66)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a path error condition
because of b3 errors. The alarm
corresponds to the prei alarm on an
NE.
Name:
SonetPathLossOfCodegroupDelineationError
Type: communicationsAlarm (4)
Probable cause:
pathLossOfCodegroupDelineationError (185)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a PLCD error. The alarm
corresponds to the plcd alarm on an
NE.
Name: SonetPathLossOfPointer
Type: communicationsAlarm (4)
Probable cause: pathLossOfPointer (64)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a PLOP error. The alarm
corresponds to the plop alarm on an
NE.
Name: SonetPathPayloadMismatch
Type: communicationsAlarm (4)
Probable cause: pathPayloadMismatch (67)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a PPLM error on a
channel, after which the channel is
set operationally down. The alarm
corresponds to the pplm alarm on an
NE.
Name: SonetPathRemoteB3Error
Type: communicationsAlarm (4)
Probable cause: pathRemoteB3Error (68)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a path error condition
that a remote NE raises because of
b3 errors received from the local NE.
The alarm corresponds to the prei
alarm on an NE.
Name: SonetPathRemoteDefectIndication
Type: communicationsAlarm (4)
Probable cause:
pathRemoteDefectIndication (65)
Severity: Major
Object Type (class):
SonetChannelMonitorSpecifics
Domain: sonetequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a SONET
port reports a remote PAIS error. The
alarm corresponds to the pais alarm
on an NE.
Alarm Attributes Additional information
(2 of 3)