EasyManua.ls Logo

Alcatel-Lucent 5620 - Procedure 6-3 to Manage Filters Using the GUI Filter Manager

Alcatel-Lucent 5620
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 — 5620 SAM LogViewer
6-12 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
6 Choose an ANSI display attribute from the drop-down list beside each of the
following parameters to specify how the CLI application displays the
corresponding text.
Normal Display—for normal application text
Trace Level Display—for trace-level log entries
Debug Level Display—for debug-level log entries
Info Level Display—for info-level log entries
Warning Level Display—for warning-level log entries
Error Level Display—for error-level log entries
Fatal Level Display—for fatal-level log entries
Filter Display—for filtered log entries
7 Click on the SAM tab to configure the parameters that are specific to the
5620 SAM.
8 Configure the following parameters by clicking in the parameter field and using
the browser form that opens to specify a directory:
Database Location—specifies the base 5620 SAM database installation
directory
Oracle Location—specifies the base 5620 SAM Oracle installation directory
NMS Root—specifies the nms directory under the base 5620 SAM server
installation directory
9 Click on the Advanced tab to configure the parameters related to LogViewer
performance.
Procedure 6-3 To manage filters using the GUI Filter Manager
Perform this procedure to create, modify, assign or delete a LogViewer filter.
1 Choose LogFilter Manager from the LogViewer main menu. The Filter Manager
applet opens.
2 Perform the following steps to add a filter.
i Click on the Add button. The Add Filter form opens.
ii Configure the Name parameter by specifying a unique name for the filter.
Caution — The parameters on the Advanced tab typically require
configuration only when LogViewer has performance problems. Consult
Alcatel-Lucent technical support before you attempt to modify a
parameter on the Advanced tab, as it may affect server performance.
Note — The Filter Manager is opened from within LogViewer, but runs
as a separate applet. This enables the dragging and dropping of filters
between Filter Manager and the Filters sub-tab of a lob tab.